| Click on photograph to enlarge | |
|

| Gross scoring damage to lead-bronze journal bearing. |
| Main Characteristics | Deep circumferential scoring of bearing surface in the direction of rotation. |
| Cause | Gross contamination of lubricating oil.
See wear
summary for further information on causes and actions. |
| Note | Note the continuous score marks and the dragging over of the bearing metal at the downstream end of the half bearing (right hand side in Photograph). |
| Possible Confusion with Other Types of Damage | Unlikely
to confuse with other failure mechanisms. |
| Comment | This was a main bearing of a three-throw reciprocating pump. The damage occurred at commissioning because the crankcase was not cleaned out before starting. |